Inverting Capacitive Resistivity (Line Electrode) Measurements with Direct Current Inversion Programs
Inverting Capacitive Resistivity (Line Electrode) Measurements with Direct Current Inversion Programs
复制标题
使用直流反演程序反演电容电阻率(线电极)测量
DOI:
--
复制
发表时间:
2010
期刊:
影响因子:
--
通讯作者:
N. Klitzsch
中科院分区:
文献类型:
--
作者:
Maik Neukirch;N. Klitzsch
The capacitive resistivity (CR) method is a time‐ and labor‐saving alternative to traditional direct current (DC) resistivity methods. The line electrode variant of CR suffers from the absence of data inversion programs as available for the DC resistivity method. Direct current inversion programs were applied to determine the resistivity distribution from CR measurements using an approximately equivalent four‐point dipole–dipole configuration. We optimized configurations to minimize the systematic error applying DC inversion programs to CR, using data based on the comparison of the two‐dimensional sensitivities of the proposed DC approximations. The optimal four‐point dipole–dipole geometry has a dipole length of 80%.