UV/Ozone treatment to decontaminate tritium contaminated surfaces
UV/Ozone treatment to decontaminate tritium contaminated surfaces
复制标题
紫外线/臭氧处理可净化氚污染的表面
DOI:
10.13182/fst95-a30597
复制
发表时间:
1995
期刊:
影响因子:
--
通讯作者:
R. Mowat
中科院分区:
文献类型:
--
作者:
J. Krasznai;R. Mowat
Tritium contamination on surfaces is often encountered during operation and maintenance of equipment at the Darlington Tritium Removal Facility and likely at other tritium handling facilities. The use of efficient decontamination techniques that produce little or no secondary wastes is desirable. At Ontario Hydro Technologies (OHT) we have been developing a process utilizing a combination of ultraviolet (UV) radiation and ozone gas to remove tritium surface contamination from materials often used in tritium service. This paper summarizes the performance of the technique. The results are encouraging because the technique is very effective, simple in terms of equipment requirements and concentrates tritium in an easily managed waste form. 7 refs., 3 figs., 2 tabs.