High-frequency ultrasound array element using thermoelastic expansion in an elastomeric film
High-frequency ultrasound array element using thermoelastic expansion in an elastomeric film
复制标题
DOI:
10.1063/1.1388027
复制
发表时间:
2001-07-23
影响因子:
4
通讯作者:
O'Donnell, M
中科院分区:
文献类型:
--
作者:
Buma, T;Spisar, M;O'Donnell, M
The thermoelastic effect was used to produce high-frequency, broadband ultrasound in water. A pulsed diode laser, followed by an erbium-doped fiber amplifier, was focused onto a light-absorbing film deposited on a glass substrate. Conversion efficiency was improved by over 20 dB using an elastomeric film instead of a more commonly used metallic one. Radiation pattern measurements show that considerable energy is radiated at +/-45 degrees for frequencies beyond 50 MHz. These results show that the thermoelastic effect can be used to produce phased arrays for high-frequency ultrasound imaging. (C) 2001 American Institute of Physics.