Study of an improved Allyl Di-Glycol carbonate sheet for high energy proton detection.
Study of an improved Allyl Di-Glycol carbonate sheet for high energy proton detection.
复制标题
用于高能质子检测的改进的烯丙基二乙二醇碳酸酯片的研究。
DOI:
10.1093/rpd/nci537
复制
发表时间:
2006
影响因子:
1
通讯作者:
M. Takada
中科院分区:
文献类型:
--
作者:
H. Ohguchi;N. Juto;S. Fujisaki;S. Migita;Y. Koguchi;M. Takada
An allyl di-glycol carbonate (ADC) sheet which has been utilised as a neutron detector for personal dosimetry has recently been studied for its application as a device for radiation exposure control for astronauts in space, where protons are the dominant radiation. It is known that the fabrication process, modified by adding some kind of antioxidant to improve the sensitivity of ADC to high energy protons, causes a substantial increase in false tracks, which disturb the automatic counting of proton tracks using the auto-image analyser. This made clear the difficulty of fabricating ADC sheets which have sufficient sensitivity to high energy protons, while maintaining a good surface. In this study, we have tried to modify the fabrication process to improve the sensitivity to high energy protons without causing a deterioration of the surface condition of ADC sheets. We have successfully created fairly good products.