Evaluation of Image Distortion in Sem by Using a Dot-Array Based Certified Reference Material.
Evaluation of Image Distortion in Sem by Using a Dot-Array Based Certified Reference Material.
复制标题
使用基于点阵的认证参考材料评估扫描电镜中的图像失真。
DOI:
10.1093/jmicro/dfab003
复制
发表时间:
2021
期刊:
影响因子:
1.8
通讯作者:
A. Kurokawa
中科院分区:
文献类型:
--
作者:
K. Kumagai;A. Kurokawa
This paper presents a quick and straightforward method to evaluate image distortion in scanning electron microscopy (SEM) using a certified reference material (CRM) as a test specimen. The CRM has a square dot-array structure, whose dot-pitch has an accredited value. By calculating the distance between each dot of the CRM via image analysis, we can detect the distortion in the image as variations of dot interval. Furthermore, by considering the uncertainty of the certified value, it is possible to quantitatively evaluate the significance of the distortion in the image. This method enables us to easily estimate the uncertainty from image distortion, which can improve the reliability of measurement by SEM.