Under monotonic force control several strength tests were performed on coupon-size masonry panels (dimensions mostly 520 x 520 x 120 mm) in order to get information on the in-plane response ofbrickwork walls. Ali specimens were made up ofpolish standard clay bricks (250 x 120 x 65mm) and a 1:0.5:4.5 portland cement-lime mortar. The response to direct shear was investigated by means ofboth the standard triplet test and the test with the predetermined single plane of the shear failure. In the latter test there is not need to measure the strength at a number of the precompression leveis in order to predict the initial shear strength. Tests with the single shear plane normal to the bed joints were also performed. The diagonal compression test has been chosen to simulate in-plane shear phenomenon related to the diagonal cracking. The test was carried out on ten masonry panels capturing the failure modes and the splitting strength. Additionally, the various strength characteristics of bricks and mortar were investigated. The strength cri teria related are also discussed. For the experimental data the simplest form of the cri teria are presented in the shear-precompression stress state. The three basic failure modes are distinguished: shear slip along the bed joints, diagonal tension cracking and shear compression fai lure. Some remarks on taking advantage of the strength parameters from triplet and diagonal compression tests are also given.