Automatic extraction of the aorta and the measurement of its diameter.

Automatic extraction of the aorta and the measurement of its diameter.
复制标题

自动提取主动脉并测量其直径。

DOI:
10.9734/bjmmr/2014/5050
复制
发表时间:
2014
期刊:
British journal of medicine and medical research
影响因子:
--
通讯作者:
S. Takanashi
S. Takanashi
中科院分区:
--
文献类型:
--
作者:
N. Mukai;Y. Tatefuku;Y. Niki;S. Takanashi

文献摘要

被引文献

相似文献

___________________________________________________________________________________________这项工作是在所有作者之间合作进行的。作者NM设计了这项研究,并撰写了手稿的初稿。作者YT进行了统计分析,并编写了程序。作者YC回顾了该方法,并对数据进行了调查。作者KN和ST从医学角度对方法和结果进行了检验。所有作者都阅读并批准了最后的手稿。摘要目的:本研究的目的是提取主动脉并测量其直径,为血管内修复(EVAR)或主动脉瓣置换术(AVR)等心脏手术的术前计划提供依据。研究设计:实验研究。方法:为了正确提取主动脉,首先要去除脊椎。然后,通过考虑主动脉,特别是主动脉弓的曲率来测量主动脉的直径。该方法的新颖之处在于:结果:即使在存在动脉瘤的情况下,该方法也能正确地取出和取出脊柱,也能取出主动脉。此外,自动测量的直径与手动测量的直径几乎相同。结论:即使脊柱与主动脉重叠,也可以取出主动脉。此外,测得的主动脉直径为20至30 mm,与正常人的平均直径几乎相同。然而,心脏的一些部分被提取为主动脉,主动脉弓的直径不正确。这些都是今后工作需要解决的问题。
___________________________________________________________________________________________ This work carried out in collaboration between all authors. Author NM designed the study, and wrote the first draft of the manuscript. Author YT performed the statistical analysis, and wrote the program. Author YC reviewed the method and investigated the data. Authors KN and ST checked the method and the results from the medical point of view. All authors read and approved the final manuscript. ABSTRACT Aims: The objective of this research is to extract the aorta and to measure its diameter for preoperative planning of heart surgeries such as Endo Vascular Aortic Repair (EVAR) or Aortic Valvular Replacement (AVR). Study Design: Experimental Study. Methodology: In order to extract the aorta correctly, the spine is removed first. Then, the diameter of the aorta is measured by considering the curvature of the aorta, especially the aortic arch. The novelty of the proposed method is as follows. Results: The spine has been extracted and removed correctly and also the aorta has been extracted with the proposed method even if there is an aneurysm in the aorta. In addition, the diameter measured automatically is almost the same as that measured manually. Conclusion: It has become possible to extract the aorta even if the spine overlaps with the aorta. In addition, the measured diameter of the aorta ranges from 20 to 30 [mm], which is almost the same as the average of normal persons’ aorta. However, some parts of the heart were extracted as the aorta, and the diameter of the aortic arch was not correct. These are the issues for future works.