Emergency EPR dosimetry technique using vacuum-stored dry nails.
Emergency EPR dosimetry technique using vacuum-stored dry nails.
复制标题
DOI:
10.1016/j.radmeas.2016.02.014
复制
发表时间:
2016-05-01
影响因子:
2
通讯作者:
McKeever SW
中科院分区:
文献类型:
--
作者:
Sholom S;McKeever SW
Human finger- and toenails have been tested with an X-band EPR technique for different conditions of nail storage. The main radiation-induced signal at g=2.005 demonstrated good stability if the samples were stored in a vacuum at room temperature after nail harvesting and irradiation. On the basis of this phenomenon, a new protocol is proposed to use the nails as possible emergency EPR dosimeters. The dosimetry protocol was tested on laboratory-exposed samples and demonstrated the ability to recover doses in the region 0-10 Gy with an estimated uncertainty of approximately 0.3-0.4 Gy for doses in the range < 2 Gy, increasing to 0.6-0.7 Gy for doses in the range 5-10 Gy.