A parallel robot to assist vitreoretinal surgery
A parallel robot to assist vitreoretinal surgery
复制标题
DOI:
10.1007/s11548-009-0374-2
复制
发表时间:
2009-11-01
影响因子:
3
通讯作者:
Mitsuishi, Mamoru
中科院分区:
文献类型:
--
作者:
Nakano, Taiga;Sugita, Naohiko;Mitsuishi, Mamoru
Purpose This paper describes the development and evaluation of a parallel prototype robot for vitreoretinal surgery where physiological hand tremor limits performance.Methods The manipulator was specifically designed to meet requirements such as size, precision, and sterilization; this has six-degree-of-freedom parallel architecture and provides positioning accuracy with micrometer resolution within the eye. The manipulator is controlled by an operator with a "master manipulator" consisting of multiple joints.Results Results of the in vitro experiments revealed that when compared to the manual procedure, a higher stability and accuracy of tool positioning could be achieved using the prototype robot.Conclusions This microsurgical system that we have developed has superior operability as compared to traditional manual procedure and has sufficient potential to be used clinically for vitreoretinal surgery.