Enhancement in Gas Pumping in a Square Channel With Two-Stage Corona Wind Generator
Enhancement in Gas Pumping in a Square Channel With Two-Stage Corona Wind Generator
复制标题
DOI:
10.1109/tia.2013.2290864
复制
发表时间:
2014-07
影响因子:
4.4
通讯作者:
A. Mazumder;F. Lai
中科院分区:
文献类型:
--
作者:
A. Mazumder;F. Lai
In this paper, the flow field inside a square channel with a two-stage electrohydrodynamic (EHD) gas pump has been critically examined by experimental measurement and numerical simulation. The EHD gas pump with 28 emitting electrodes in each stage is tested for a wide range of operating voltages starting from the corona onset voltage up to 28 kV for further improvement in its performance over a single-stage one. It has been shown that the two-stage EHD gas pump can produce and sustain gas flows with a maximum velocity of 1.8 m/s. Its maximum performance of 36 L/s/W is better than that of conventional cooling fans used in personal computers. The implication for its application in thermal management and heat transfer enhancement has also been discussed.