Frequency and Modulation Index Related Effects in Continuous and Discontinuous Modulated Y-Inverter for Motor-Drive Applications
Frequency and Modulation Index Related Effects in Continuous and Discontinuous Modulated Y-Inverter for Motor-Drive Applications
复制标题
用于电机驱动应用的连续和不连续调制 Y 型逆变器中频率和调制指数的相关影响
DOI:
--
复制
发表时间:
2022
期刊:
影响因子:
--
通讯作者:
A. Castellazzi
中科院分区:
文献类型:
--
作者:
H. J. Jaber;A. Castellazzi
The effect of the pulse-width modulation scheme on the efficiency of a three-phase Y-inverter with a wide range of output voltages and currents is investigated experimentally in this paper. The efficiency measurements obtained while conducting experiments on a GaN-based Y-inverter prototype indicate that no pulse-width modulation scheme results in higher efficiency of the Y-inverter over the entire range of motor operation. In other words, depending on the operating conditions, a discontinuous PWM results in a higher or lower efficiency than a continuous sinusoidal PWM. As a result, there is a chance that using a hybrid modulation strategy will improve the efficiency of the Y-inverter. Furthermore, the distortion effect caused by inappropriate inductor and capacitor value selection is highlighted.