Experimental evaluation of clad metallic buffer rods for high temperature ultrasonic measurements
复制标题
DOI:
10.1016/s0963-8695(99)00042-0
复制
发表时间:
2000-04-01
影响因子:
4.2
通讯作者:
Parent, L
中科院分区:
文献类型:
--
作者:
Jen, CK;Legoux, JG;Parent, L
The fabrication, evaluation and several applications of metallic buffer rods consisting of a core and a cladding are presented. The clad rods can have a taper shape and the cladding is fabricated by thermal spray techniques. Clad rods as long as Im have been fabricated. Experimental results show that the ultrasonic signals detected at 5 MHz with these buffer rods have very high signal to noise ratio (>35 dB) for both longitudinal and sheer waves in a reflection mode. Applications to the measurement of the thickness of hot plates and molten metals up to 960 degrees C and to the on-line monitoring of polymer extrusion are reported. Crown copyright (C) 2000 Published by Elsevier Science Ltd. All rights reserved.