Effect of attrition on SO2 capture by limestone under pressurized fluidized bed combustion conditions: comparison between a mathematical model of SO2 capture by single limestone particle under attrition condition and SO2 capture in a large-scale PFBC
Effect of attrition on SO2 capture by limestone under pressurized fluidized bed combustion conditions: comparison between a mathematical model of SO2 capture by single limestone particle under attrition condition and SO2 capture in a large-scale PFBC
复制标题
DOI:
10.1016/s0009-2509(01)00298-6
复制
发表时间:
2001-12
影响因子:
4.7
通讯作者:
T. Shimizu;M. Peglow;Shinichi Sakuno;Nobuhiro Misawa;N. Suzuki;H. Ueda;H. Sasatsu;H. Gotou
中科院分区:
文献类型:
--
作者:
T. Shimizu;M. Peglow;Shinichi Sakuno;Nobuhiro Misawa;N. Suzuki;H. Ueda;H. Sasatsu;H. Gotou
Attrition rate of limestone and SO2 capture rate in a large scale pressurized fluidized bed combustor was evaluated. The average attrition rate (reduction rate of radius) was found to be approximately 0.2–. The SO2 capture rate per unit external surface area of bed material was found to be independent on SO2 concentration in the flue gas. A mathematical model of SO2 capture by single limestone particle under attrition conditions was proposed. Apparent reaction order with respect to SO2 concentration was close to zero when attrition was taken into consideration. It was suggested that the rate of SO2 capture in the present PFBC was governed by the limestone attrition.