Modulation cues influence binaural masking-level difference in masking-pattern experiments.
Modulation cues influence binaural masking-level difference in masking-pattern experiments.
复制标题
调制线索影响掩蔽模式实验中的双耳掩蔽水平差异。
DOI:
10.1121/1.3681925
复制
发表时间:
2012
期刊:
影响因子:
--
通讯作者:
J. Verhey
中科院分区:
文献类型:
--
作者:
M. Nitschmann;J. Verhey
Binaural masking patterns show a steep decrease in the binaural masking-level difference (BMLD) when masker and signal have no frequency component in common. Experimental threshold data are presented together with model simulations for a diotic masker centered at 250 or 500 Hz and a bandwidth of 10 or 100 Hz masking a sinusoid interaurally in phase (S(0)) or in antiphase (S(π)). Simulations with a binaural model, including a modulation filterbank for the monaural analysis, indicate that a large portion of the decrease in the BMLD in remote-masking conditions may be due to an additional modulation cue available for monaural detection.