Dual-head gamma camera 2-[fluorine-18]-fluoro-2-deoxy-d-glucose positron emission tomography in oncological patients: effects of non-uniform attenuation correction on lesion detection
Dual-head gamma camera 2-[fluorine-18]-fluoro-2-deoxy-d-glucose positron emission tomography in oncological patients: effects of non-uniform attenuation correction on lesion detection
复制标题
双头伽玛相机 2-[氟-18]-氟-2-脱氧-d-葡萄糖正电子发射断层扫描在肿瘤患者中的应用:非均匀衰减校正对病变检测的影响
DOI:
--
复制
发表时间:
1999
期刊:
影响因子:
--
通讯作者:
U. Buell
中科院分区:
文献类型:
--
作者:
M. Zimny;H. Kaiser;U. Cremerius;P. Reinartz;M. Schreckenberger;O. Sabri;U. Buell
Abstract. The purpose of this study was to evaluate a dual head coincidence gamma camera (DH-PET) equipped with single-photon transmission for 2-[fluorine-18]-fluoro-2-deoxy-d-glucose (FDG) imaging in oncological patients. Forty-five patients with known or suspected malignancies, scheduled for a positron emission tomography (PET) scan, were first studied with a dedicated ring PET and subsequently with DH-PET. All patients underwent measured attenuation correction using germanium-68 rod sources for ring PET and caesium-137 sources for DH-PET. Ring PET emission scan was started 64±17 min after intravenous administration of 235±42 MBq FDG. DH-PET emission followed 160±32 min after i.v. FDG. Attenuation-corrected and non-attenuation-corrected images were reconstructed for ring PET and DH-PET. The image sets were evaluated independently by three observers blinded to clinical data and to results of conventional imaging. Attenuation-corrected ring PET as the standard of reference depicted 118 lesions, non-attenuation-corrected ring PET 113 (96%) lesions, and attenuation-corrected DH-PET and non-attenuation-corrected DH-PET, 101 (86%) and 84 (71%) lesions, respectively (P<0.05). The lesion detection rate of attenuation-corrected and non-attenuation-corrected DH-PET was almost similar for lesions >20 mm, whereas attenuation correction increased the detection rate from 60% to 80% for lesions ≤20 mm (P<0.01). A patient-based analysis revealed concordant results relative to attenuation-corrected ring PET for non-attenuation-corrected ring PET, attenuation-corrected DH-PET and non-attenuation-corrected DH-PET in 42 (93%), 36 (80%) and 31 (69%) patients, respectively. Differences might have influenced patient management in two (4%), six (13%) and ten (22%) patients, respectively. In conclusion, measured attenuation correction markedly improves the lesion detection capability of DH-PET. With measured attenuation correction the diagnostic performance of DH-PET is closer to that of dedicated ring PET.
影响因子:
19.7
作者:
Zasadny,KR;Kison,PV;Quint,LE;Wahl,RL
通讯作者:
Wahl,RL