TEXT upgrade far‐infrared interferometer system

TEXT upgrade far‐infrared interferometer system
复制标题

DOI:
10.1063/1.1141766
复制
发表时间:
1990-10
影响因子:
1.6
通讯作者:
G. Hallock;M. L. Gartman;R. Castles;K. Chiang;A. S. Rahman
G. Hallock;M. L. Gartman;R. Castles;K. Chiang;A. S. Rahman
中科院分区:
工程技术4区
文献类型:
--
作者:
G. Hallock;M. L. Gartman;R. Castles;K. Chiang;A. S. Rahman

文献摘要

被引文献

相似文献

正在开发一种高分辨率二维干涉仪,用于测量 TEXT 升级版托卡马克中的电子密度分布。出色的端口访问允许水平和垂直弦,这将用于解决等离子体不对称性。采用紧密的通道间隔来提供良好的空间分辨率。此外,该系统可以在成像模式下运行,以解决 H 模式操作中预期的陡峭梯度。
A high‐resolution 2‐D interferometer is being developed to measure electron density profiles in the TEXT‐upgrade tokamak. Excellent port access allows both horizontal and vertical chords, which will be used to resolve plasma asymmetries. Close channel spacing is employed to give good spatial resolution. In addition, the system can be operated in an imaging mode to resolve the steep gradients expected in H‐mode operation.