EXPERIMENTAL STUDIES ON THE EMISSION OF PM_(10) AND PM_(2.5) FROM COAL-FIRED BOILER
EXPERIMENTAL STUDIES ON THE EMISSION OF PM_(10) AND PM_(2.5) FROM COAL-FIRED BOILER
复制标题
DOI:
--
复制
发表时间:
2003
期刊:
影响因子:
--
通讯作者:
Cen Ke-fa
中科院分区:
文献类型:
--
作者:
Cen Ke-fa
By using seven-stage impact classifiers, the fine dust(fly ash) from a coal-fired boiler is sampled. One classifier is located in the entrance of dust catcher and another in its exit. The results show that the mass ratios of PM10 and PM2.5 are approximately 92.47% and 35.56% respectively, comparatively higher than that before the dust catcher. Efficiency of the dust catcher for fine dust is lower than that for normal amounts to 90.6% only. It is summarized that the fineness of pulverized coal, the operation mode of pulverizing system and boiler load are the main affecting factors on the size distribution of dust(fly ash). It is known from the study that the finer pulverized coal is, the finer emitted fly ash will be. In addition, the fly ash becomes finer under exhaust air operation, and the reduction of boiler load can improve the dust collection efficiency.