Impact of platform switching on marginal peri-implant bone-level changes. A systematic review and meta-analysis.

Impact of platform switching on marginal peri-implant bone-level changes. A systematic review and meta-analysis.
复制标题

DOI:
10.1111/clr.12339
复制
发表时间:
2015-03
影响因子:
4.3
通讯作者:
Hertel M
Hertel M
中科院分区:
工程技术2区
文献类型:
--
作者:
Strietzel FP;Neumann K;Hertel M

文献摘要

参考文献

被引文献

相似文献

为了解决焦点问题,与平台匹配(PM)种植体-基台配置的种植体相比,平台切换(PS)是否会影响内腔种植体周围的边缘骨水平(MBL)变化?使用PubMed、Web of Science、Journals@Ovid全文和Embase等电子数据库进行系统的文献检索,手动检索2005年至2013年6月发表的人类随机临床试验(rct)和前瞻性临床对照队列研究(PCCS),这些研究报告了PS-种植体与pm -种植体-基台连接时MBL的变化。22篇出版物符合系统评价的条件。对15项随机对照试验和7项PCCS的定性分析显示,更多的研究(13项随机对照试验和3项PCCS)显示,与pm -种植体-基台连接相比,PS-种植体周围的平均边缘骨损失显著减少,这表明PS技术有明显的发展趋势。一项包含13项随机对照试验的荟萃分析显示,PS种植体的平均MBL变化(0.49 mm [CI95% 0.38; 0.60])显著低于PM种植体(1.01 mm [CI95% 0.62; 1.40] (P < 0.0001)。荟萃分析显示,与pm -种植体-基台配置相比,PS种植体的平均MBL变化明显更少。本文纳入的研究大多显示偏倚风险不明确且较高,随访期相对较短。定性分析显示,与PM技术相比,PS技术更倾向于预防或减少种植体周围边缘骨丢失。由于纳入研究的异质性,其结果需要谨慎解释。
To address the focused question, is there an impact of platform switching (PS) on marginal bone level (MBL) changes around endosseous implants compared to implants with platform matching (PM) implant-abutment configurations? A systematic literature search was conducted using electronic databases PubMed, Web of Science, Journals@Ovid Full Text and Embase, manual search for human randomized clinical trials (RCTs) and prospective clinical controlled cohort studies (PCCS) reporting on MBL changes at implants with PS-, compared with PM-implant-abutment connections, published between 2005 and June 2013. Twenty-two publications were eligible for the systematic review. The qualitative analysis of 15 RCTs and seven PCCS revealed more studies (13 RCTs and three PCCS) showing a significantly less mean marginal bone loss around implants with PS- compared to PM-implant-abutment connections, indicating a clear tendency favoring the PS technique. A meta-analysis including 13 RCTs revealed a significantly less mean MBL change (0.49 mm [CI95% 0.38; 0.60]) at PS implants, compared with PM implants (1.01 mm [CI95% 0.62; 1.40] (P < 0.0001). The meta-analysis revealed a significantly less mean MBL change at implants with a PS compared to PM-implant-abutment configuration. Studies included herein showed an unclear as well as high risk of bias mostly, and relatively short follow-up periods. The qualitative analysis revealed a tendency favoring the PS technique to prevent or minimize peri-implant marginal bone loss compared with PM technique. Due to heterogeneity of the included studies, their results require cautious interpretation.
DOI: 10.1016/s0022-3913(09)60060-3
发表时间: 2009-05-01
影响因子: 4.6
作者:
Kielbassa, Andrej M.;Martinez-de Fuentes, Rafael;Sanz, Mariano
通讯作者: Sanz, Mariano
DOI: 10.1016/j.joms.2007.03.024
发表时间: 2007-07-01
影响因子: 1.9
作者:
Huerzeler, Markus;Fickl, Stefan;Wachtel, Hannes C.
通讯作者: Wachtel, Hannes C.
DOI: 10.1034/j.1600-0501.2003.140102.x
发表时间: 2003-02-01
影响因子: 4.3
作者:
Feloutzis, A;Lang, NP;Kornman, KS
通讯作者: Kornman, KS
DOI: 10.1016/j.jpor.2012.02.002
发表时间: 2012-10-01
影响因子: 3.6
作者:
Cunha, Cacilda;Anchieta, Rodolfo Bmniera;Rocha, Eduardo Passos
通讯作者: Rocha, Eduardo Passos
DOI: 10.1111/j.1600-051x.2007.01155.x
发表时间: 2007-12-01
影响因子: 6.7
作者:
Becker, Juergen;Ferrari, Daniel;Schwarz, Frank
通讯作者: Schwarz, Frank