Auscultatory mean blood pressure.

Auscultatory mean blood pressure.
复制标题

听诊平均血压。

DOI:
10.1007/bf02842484
复制
发表时间:
1990
期刊:
Journal of clinical monitoring
影响因子:
--
通讯作者:
Geddes,LA
Geddes,LA
中科院分区:
--
文献类型:
--
作者:
Davis,GJ;Geddes,LA

文献摘要

相似文献

This study examined the relationship between direct mean arterial blood pressure and cuff pressure for the maximum acoustic index calculated from the Korotkoff sounds in the dog. The acoustic index was computed by summing the squares of amplitudes in each Korotkoff sound complex, thereby providing a measure of acoustic energy content. Mean arterial pressure was compared with cuff pressure for the maximum acoustic index. Ten mongrel dogs were fitted with appropriately sized blood-pressure cuffs containing a microphone mounted inside the bladder and positioned over the brachial artery. The Korotkoff sounds, cuff pressure, and direct arterial pressure were recorded over a range of mean arterial pressures (23 to 155 mm Hg), achieved by manipulating the depth of anesthesia with halothane. It was found that cuff pressure at the maximum acoustic index overestimated mean arterial blood pressure by a mean of 14% (range, -8 to + 30%).