The Vertical Traverse Stage in Vacuum Condition
The Vertical Traverse Stage in Vacuum Condition
复制标题
真空状态下的垂直移动台
DOI:
10.1299/jsmec1988.33.61
复制
发表时间:
1990
期刊:
影响因子:
--
通讯作者:
Makoto Higomura
中科院分区:
文献类型:
--
作者:
Masaru Ohtsuka;M. Furukawa;Makoto Higomura
A vertical traverse wafer positioning stage was developed for X-ray stepper application in synchrotron radiation (SR) as an X-ray source. To ensure high accuracy of movement in vacuum /low-pressure helium conditions, the stage construction was split up into a coarse stepping stage and a fine positioning stage. For the coarse stepping stage, a linear air hydrostatic bearing (LAB) with a noncontact sealing device was developed to avoid lubrication problems. For the fine positioning stage, a multiaxis leaf spring guided and piezoelectric actuators employed stage was developed to attain high rigidity. The air leakage rate from each noncontact sealing device was less than 5.7x10-4 Pa·m3/sec, so that the pressure of the vacuum chamber could reach 3 x 10-3 Pa. Experiments on the coarse stepping stage show rotational movement error such as pitching and yawing to be less than ±6μrad with a repeatability of less than ±1μrad. The multiaxis fine positioning stage is also proved to have a sufticient small movement error.