Vibrating-Wire, Supercooled Liquid Water Content Sensor Calibration and Characterization Progress
Vibrating-Wire, Supercooled Liquid Water Content Sensor Calibration and Characterization Progress
复制标题
振弦式过冷液态水含量传感器校准和表征进展
DOI:
10.2514/6.2016-4055
复制
发表时间:
2016
影响因子:
2.2
通讯作者:
F. Bunt
中科院分区:
文献类型:
--
作者:
M. King;J. Bognar;D. Guest;F. Bunt
NASA conducted a winter 2015 field campaign using weather balloons at the NASA Glenn Research Center to generate a validation database for the NASA Icing Remote Sensing System. The weather balloons carried a specialized, disposable, vibrating-wire sensor to determine supercooled liquid water content aloft. Significant progress has been made to calibrate and characterize these sensors. Calibration testing of the vibrating-wire sensors was carried out in a specially developed, low-speed, icing wind tunnel, and the results were analyzed. The sensor ice accretion behavior was also documented and analyzed. Finally, post-campaign evaluation of the balloon soundings revealed a gradual drift in the sensor data with increasing altitude. This behavior was analyzed and a method to correct for the drift in the data was developed.