Comparative study of circumferential clasp retention force for titanium and cobalt-chromium removable partial dentures
Comparative study of circumferential clasp retention force for titanium and cobalt-chromium removable partial dentures
复制标题
DOI:
10.1067/mpr.2002.128128
复制
发表时间:
2002-09-01
影响因子:
4.6
通讯作者:
Bezzon, OL
中科院分区:
文献类型:
--
作者:
Rodrigues, RCS;Ribeiro, RF;Bezzon, OL
Statement of problem. The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies to support its use.Purpose. The objective of this study was to compare circumferential RPD clasps made of commercially pure titanium and identical clasps made of 2 different cobalt (Co)-chromium (Cr) alloys by testing insertion/removal and radiographically inspecting the casts for defects.Material and methods. On refractory casts that represent a partially edentulous mandibular right hemi-arch segment, 36 frameworks were cast from commercially pure titanium (n = 12) and 2 Co-Cr alloys (n = 12 each) with identical prefabricated patterns and the manufacturer-designated investment and casting technique. Each group was divided into 2 subgroups, corresponding to .25-mm and .50-mm undercuts, respectively. No polishing procedures were performed to ensure uniformity. Only nodules and burs were carefully removed with tungsten burs under magnification when necessary. The specimens were radiographed and subjected to an insertion/removal test simulating 5 years of framework use. The data were subjected to analysis of variance and the Tukey complementary rest (P