文献摘要

被引文献

相似文献

通过测量释放后过滤收集的血小板的5-羟色胺含量来监测血小板致密颗粒释放反应。灵敏的HPLC-荧光分析允许使用小体积(25-50 μl)血浆和全血评估释放。由于过滤作用的快速停止,可在短至1秒的时间内检查释放。凝血酶刺激(1 U/ml)释放的半衰期为2-3 s,对于稀释的全血和血浆样品,在60 s释放期内观察到的凝血酶刺激释放的EC 50值为0.01-0.03 U/ml。
The platelet dense granule release reaction was monitored by measuring the serotonin content of platelets collected by filtration following release. Sensitive HPLC-fluorometric analysis permitted release to be assessed using small (25–50 μl) volumes of plasma and whole blood. Release could be examined for periods as short as 1 s due to the rapid stoppage effected by filtration. The half-life of thrombin-stimulated (1 U/ml) release was 2–3 s, the EC50values observed for thrombinstimulated release over a 60-s release period were 0.01–0.03 U/ml for diluted whole blood and plasma samples.