Comparison of simultaneous and sequential two-view registration for 3D/2D registration of vascular images

Comparison of simultaneous and sequential two-view registration for 3D/2D registration of vascular images
复制标题

DOI:
10.1007/11566489_30
复制
发表时间:
2005-01-01
期刊:
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 2
影响因子:
--
通讯作者:
Bullitt, E
Bullitt, E
中科院分区:
其他
文献类型:
--
作者:
Pathak, C;Van Horn, M;Bullitt, E

文献摘要

被引文献

相似文献

Accurate 3D/2D vessel registration is complicated by issues of image quality, occlusion, and other problems. This study performs a quantitative comparison of 3D/2D vessel registration in which vessels segmented from preoperative CT or MR are registered with biplane x-ray angiograms by either a) simultaneous two-view registration with advance calculation of the relative pose of the two views, or b) sequential registration with each view. We conclude on the basis of phantom studies that, even in the absence of image errors, simultaneous two-view registration is more accurate than sequential registration. In more complex settings, including clinical conditions, the relative accuracy of simultaneous two-view registration is even greater.