Falling Film of Ionic Liquid-Water Binary Solutions on a Uniformly Heated Vertical Wall
Falling Film of Ionic Liquid-Water Binary Solutions on a Uniformly Heated Vertical Wall
复制标题
DOI:
10.1115/1.4004872
复制
发表时间:
2012
影响因子:
--
通讯作者:
Jing Peng;Mingming Wang;J. Geng;Youting Wu;Zhibing Zhang
中科院分区:
文献类型:
--
作者:
Jing Peng;Mingming Wang;J. Geng;Youting Wu;Zhibing Zhang
The flow characteristics of falling film of amino acid ionic liquid (AAIL) aqueous solution on a uniformly heated vertical plane have been experimentally studied. The infrared images and temperature profiles have been determined and used to analyze the fluid flow. It is proven that the Marangoni effect exists widely and has significant influence on the flow region of falling film. A novel flow pattern is additionally observed when the mass fraction of AAIL is 30%. The flow patterns are also shown to be affected by the wall-liquid temperature differential, the flow rate and the concentration of solute. The experimental results of AAIL falling film are expected to be helpful for the further industrial application of ionic liquids.