Bimetal Strip Hydrogen Gas Detectors

Bimetal Strip Hydrogen Gas Detectors
复制标题

双金属片氢气检测仪

DOI:
10.1063/1.1684100
复制
发表时间:
1969
影响因子:
1.6
通讯作者:
P. Shaver
P. Shaver
中科院分区:
工程技术4区
文献类型:
--
作者:
P. Shaver

文献摘要

被引文献

相似文献

结果表明,以钯银合金为活性组分的探测条是一种灵敏的气态氢探测器。用这种技术已经检测到STP氮气中的氢浓度低至50 ppm。在200-300°C的钢带操作温度下获得快速响应时间。实验观察到的这些条的稳态行为是在良好的协议与理论。
It is shown that bimetal strips which use palladium—silver alloys as the active component are sensitive detectors of gaseous hydrogen. Concentrations of hydrogen in STP nitrogen as low as 50 ppm have been detected with this technique. Fast response times are obtained at bimetal strip operating temperatures of 200–300°C. The experimentally observed steady state behavior of these strips is in good agreement with theory.