Bimetal Strip Hydrogen Gas Detectors
Bimetal Strip Hydrogen Gas Detectors
复制标题
双金属片氢气检测仪
DOI:
10.1063/1.1684100
复制
发表时间:
1969
影响因子:
1.6
通讯作者:
P. Shaver
中科院分区:
文献类型:
--
作者:
P. Shaver
It is shown that bimetal strips which use palladium—silver alloys as the active component are sensitive detectors of gaseous hydrogen. Concentrations of hydrogen in STP nitrogen as low as 50 ppm have been detected with this technique. Fast response times are obtained at bimetal strip operating temperatures of 200–300°C. The experimentally observed steady state behavior of these strips is in good agreement with theory.