Superoxide sensor based on hemin modified electrode
Superoxide sensor based on hemin modified electrode
复制标题
DOI:
10.1016/s0925-4005(00)00575-x
复制
发表时间:
2000-11-01
影响因子:
8.4
通讯作者:
Scheller, FW
中科院分区:
文献类型:
--
作者:
Chen, J;Wollenberger, U;Scheller, FW
A hemin modified pyrolytic graphite (PG) electrode was prepared and applied for the electrochemical determination of superoxide. The rate constant of heterogeneous electron transfer of adsorbed hemin was determined with cyclic voltammetry (CV) to be 15 s(-1). The hemin modified electrode was applied to detect superoxide radicals produced by xanthine oxidase (XOD) catalyzed hypoxanthine oxidation. Sensitivity was higher than compared to the established cytochrome c (cyt c)-based sensor. The antioxidative activity of superoxide dismutase (SOD) and uric acid was also investigated. (C) 2000 Elsevier Science B.V. All rights reserved.