Safety of high-intensity corneal collagen crosslinking

Safety of high-intensity corneal collagen crosslinking
复制标题

DOI:
10.1016/j.jcrs.2013.11.041
复制
发表时间:
2014-08-01
影响因子:
2.8
通讯作者:
Pallikaris, Aristophanis I.
Pallikaris, Aristophanis I.
中科院分区:
医学2区
文献类型:
--
作者:
Kymionis, George D.;Grentzelos, Michael A.;Pallikaris, Aristophanis I.

文献摘要

被引文献

相似文献

目的:评价一种新型高强度角膜胶原交联治疗圆锥角膜的安全性。单位:希腊克里特岛伊拉克利翁克里特岛大学医学院克里特岛Vardinoyiannion眼科研究所。设计:前瞻性介入病例系列。方法:进行性圆锥角膜患者使用一种新的治疗方案,9 mW/cm(2)照射持续10分钟。术前及术后3个月分别评估两组患者的再上皮化率、内皮细胞密度(ECD)、矫正视力(CDVA)、角膜斜度平度数(K)。结果:9例患者(10只眼)入组。所有患者均无术中及术后早期并发症。术后3个月ECD差异无统计学意义(P= 0.169)。CDVA由术前的0.19 logMAR +/- 0.20 (SD)改善至术后3个月的0.10 +/- 0.16 logMAR;但无显著性改善(P= 0.141)。CDVA无眼损线。平均陡K读数从术前的48.04 +/- 2.57屈光度(D)下降到术后3个月的46.51 +/- 2.81屈光度(P= 0.047);术后平均扁平K读数无显著变化(P= 0.285)。结论:角膜胶原在9 mW/cm(2)辐照下交联10分钟不会引起ECD或术中或术后早期并发症的显著变化。手术后3个月没有患者丢失CDVA线。
PURPOSE: To evaluate the safety of a new high-intensity corneal collagen crosslinking (CXL) treatment protocol for keratoconus.SETTING: Vardinoyiannion Eye Institute of Crete, Faculty of Medicine, University of Crete, Heraklion, Crete, Greece.DESIGN: Prospective interventional case series.METHODS: Patients with progressive keratoconus had CXL using a new treatment protocol with 9 mW/cm(2) irradiance for duration of 10 minutes. The rate of reepithelialization, endothelial cell density (ECD), corrected distance visual acuity (CDVA), and steep and flat keratometry (K) values were evaluated preoperatively and 3 months postoperatively.RESULTS: Nine patients (10 eyes) were enrolled. No intraoperative or early postoperative complications were observed in any patient. The ECD did not change significantly 3 months postoperatively (P=.169). The CDVA improved from 0.19 logMAR +/- 0.20 (SD) preoperatively to 0.10 +/- 0.16 logMAR 3 months postoperatively; however, the improvement did not attain significance (P=.141). No eye lost lines of CDVA. The mean steep K readings decreased significantly from 48.04 +/- 2.57 diopters (D) preoperatively to 46.51 +/- 2.81 D 3 months postoperatively (P=.047); the mean flat K readings did not change significantly postoperatively (P=.285).CONCLUSIONS: Corneal collagen crosslinking at 9 mW/cm(2) irradiance for 10 minutes did not cause significant changes in ECD or intraoperative or early postoperative complications. None patient lost a line of CDVA 3 months after the procedure.