Impact of Pressure and Temperature on Hydrogen Permeation in PEM Water Electrolyzers Operated at Asymmetric Pressure Conditions
Impact of Pressure and Temperature on Hydrogen Permeation in PEM Water Electrolyzers Operated at Asymmetric Pressure Conditions
复制标题
压力和温度对在不对称压力条件下运行的 PEM 水电解槽中氢气渗透的影响
DOI:
10.1149/07514.1081ecst
复制
发表时间:
2016
期刊:
影响因子:
--
通讯作者:
K. Sundmacher
中科院分区:
文献类型:
--
作者:
P. Trinke;B. Bensmann;S. Reichstein;R. Hanke-Rauschenbach;K. Sundmacher
Water electrolyzers are predominantly operated at elevated pressures. This is especially favorable in the context of the subsequent utilization of the produced hydrogen eg due to the more efficient, electrochemical and isothermal hydrogen compression or less effort for hydrogen drying (1). However, higher pressures lead to higher cross-permeation of the product gases in electrolysis cells.