Remote CO, COS, CO2, SO2, HCl detection and temperature estimation of volcanic gas
Remote CO, COS, CO2, SO2, HCl detection and temperature estimation of volcanic gas
复制标题
火山气体远程CO、COS、CO2、SO2、HCl检测及温度估算
DOI:
--
复制
发表时间:
1997
期刊:
影响因子:
--
通讯作者:
K. Notsu
中科院分区:
文献类型:
--
作者:
Toshiya Mori;K. Notsu
Volcanic gas from an inaccessible fumarole at Aso volcano, Japan, was recently measured with a Fourier Transform InfraRed (FT‐IR) spectral radiometer. Absorption features of CO, COS, CO2, SO2, and HCl were identified in the volcanic plume spectra. This is the first time the five volcanic gas components are detected simultaneously by a remote technique. Based on the measured CO/CO2 ratio of 2.6 × 10−3, the equilibrium temperature of the volcanic gas is estimated to be 750° ± 120°C.