A New Biomechanical Deformation Response Parameter: Change in Central Corneal Thickness During Air Puff Induced Corneal Deformation.
A New Biomechanical Deformation Response Parameter: Change in Central Corneal Thickness During Air Puff Induced Corneal Deformation.
复制标题
一种新的生物力学变形响应参数:吹气引起角膜变形期间中央角膜厚度的变化。
DOI:
10.1080/02713683.2024.2338228
复制
发表时间:
2024
影响因子:
2
通讯作者:
Roberts,CynthiaJ
中科院分区:
文献类型:
--
作者:
Okon,MonicaD;Ma,Yanhui;Nguyen-Rudy,BAudrey;Roberts,CynthiaJ
PurposeTo investigate the percent change in central corneal thickness (%ΔCCT) during air-puff-induced deformation as an indicator of corneal biomechanical response.MethodsFortyex vivohuman eyes from forty donors were imaged using the CorVis ST at experimentally controlled intraocular pressure (IOP) of 10, 20, 30, and 40 mmHg, followed by uniaxial strip testing to calculate tensile modulus. The CorVis ST research software tracked the anterior and posterior cornea edges and determined the dynamic corneal response (DCR) parameters. Eyes were excluded if image quality or posterior tracking issues were present. Custom algorithms were used to calculate CCT during deformation using a ray-tracing method to correct for Scheimpflug and optical distortion within each image. Correlation and stepwise regression analyses between the shape-related DCR parameters and %ΔCCT were conducted. A mixed model analysis was performed to test the effect of IOP and the strongest significant predictors of the stepwise regression on %ΔCCT. The significance threshold was set top< 0.05.ResultsThirty eyes were ultimately analyzed and CCT increased significantly from the pre-deformation state to the highest concavity state at each IOP level (p< 0.001). IOP and multiple shape DCRs were found to be significantly related to %ΔCCT (p< 0.0001). The strongest predictor of %ΔCCT was integrated inverse radius (IIR) (p< 0.0001; partial R2= 0.4772) with no other parameter having a partial R2value greater than 0.04. The mixed model analysis showed that IIR was the sole predictor (p= 0.0098) and IOP was no longer significant as a single predictor. However, the interaction of IIR with IOP (p= 0.0023) had a significant effect on %ΔCCT.ConclusionPercent change in CCT is influenced by corneal stiffness as indicated by the significant relationship with IIR. The %ΔCCT may be a potential biomarker for determining differences in corneal deformation response with corneal diseases.
影响因子:
2.8
作者:
Roberts CJ;Dupps WJ Jr
通讯作者:
Dupps WJ Jr
影响因子:
4.4
作者:
Winkler, Moritz;Chai, Dongyul;Jester, James V.
通讯作者:
Jester, James V.
影响因子:
1.9
作者:
Lopes BT;Roberts CJ;Elsheikh A;Vinciguerra R;Vinciguerra P;Reisdorf S;Berger S;Koprowski R;Ambrósio R Jr
通讯作者:
Ambrósio R Jr