Imaging of human tooth enamel using ultrasound
Imaging of human tooth enamel using ultrasound
复制标题
DOI:
10.1109/tmi.2003.809141
复制
发表时间:
2003-04-01
影响因子:
10.6
通讯作者:
Brown, ER
中科院分区:
文献类型:
--
作者:
Culjat, M;Singh, RS;Brown, ER
This paper reports the results of a complete circumferential scan of a human tooth and its underlying dentino-enamel junction using ultrasound at frequencies in the 10-MHz range. The imagery shows clearly a two-dimensional contour of the dentino-enamel junction with a depth and lateral resolution of approximately 100 mum and 750 mum, respectively. The resulting sonograph is compared with an optical micrograph of the same tooth to verify the accuracy of the ultrasonic technique. The results are a significant step toward the biolocation of submillimeter size features within the tooth volume.