A highly selective chemosensor for detection and determination of cyanide by using an indicator displacement assay and PC-ANN and its logic gate behavior

A highly selective chemosensor for detection and determination of cyanide by using an indicator displacement assay and PC-ANN and its logic gate behavior
复制标题

DOI:
10.1016/j.snb.2014.10.053
复制
发表时间:
2015-03-31
影响因子:
8.4
通讯作者:
Bordbar, Mohammad Mahdi
Bordbar, Mohammad Mahdi
中科院分区:
化学1区
文献类型:
--
作者:
Khajehsharifi, Habibollah;Bordbar, Mohammad Mahdi

文献摘要

被引文献

相似文献

建立了一种基于锌试剂与氰化物竞争结合的金属络合指示剂置换法(M-IDA)测定氰化物浓度。在某些真实的样品中,CN-的浓度可在pH = 9.0时通过测定484 nm处的吸光度来测定。该系统显示了XNOR逻辑功能,使用Zn(II)和氰化物作为化学输入,并且Zincon的颜色强度(在484 nm处)作为输出。在15 s以下的快速响应中,检出限为1.92 × 10 ~(-7)mol L ~(-1)(0.005 ppm),其它阴离子物质不干扰。采用PC-ANN算法提高了系统的工作范围。采用氰化物检测法测定生物样品中的氰化物。(C)2014爱思唯尔有限公司版权所有。
A metal complexing indicator displacement assay (M-IDA) based on competition between Zincon and Cyanide for binding with Zn (II) was developed to determine cyanide concentration. The concentration of CN- can be determined at pH = 9.0 in some real sample by measuring the absorbance at 484 nm. This system showed a XNOR logic function using Zn (II) and cyanide as chemical inputs and the color intensity of Zincon (at 484 nm) as output. cyanide can be detected with a detection limit of 1.92 x 10(-7) mol L-1 (0.005 ppm) in a fast response below 15 s and no interference of other anionic materials. The working range was improved by using PC-ANN algorithm. Cyanide detection method was applied to determine cyanide anion in biological samples. (C) 2014 Elsevier B.V. All rights reserved.