Electron density fluctuation measurements using a multichannel microwave interferometer in GAMMA 10
Electron density fluctuation measurements using a multichannel microwave interferometer in GAMMA 10
复制标题
DOI:
10.1063/1.2227445
复制
发表时间:
2006-09
影响因子:
1.6
通讯作者:
M. Yoshikawa;Y. Shima;Toshiaki Matsumoto;A. Nakahara;N. Yanagi;A. Itakura;H. Hojo;Takayuki Kobayashi;K. Matama;Y. Tatematsu;T. Imai;J. Kohagura;M. Hirata;Y. Nakashima;T. Cho
中科院分区:
文献类型:
--
作者:
M. Yoshikawa;Y. Shima;Toshiaki Matsumoto;A. Nakahara;N. Yanagi;A. Itakura;H. Hojo;Takayuki Kobayashi;K. Matama;Y. Tatematsu;T. Imai;J. Kohagura;M. Hirata;Y. Nakashima;T. Cho
Measurement of fluctuation in plasma is important for studying the improvement in plasma confinement by the formation of the plasma confinement potential. The density fluctuation is observed by microwaves by methods such as interferometry, reflectometry and Fraunhofer diffraction method. We have constructed a new multichannel microwave interferometer to measure the plasma density and fluctuation radial profiles in a single plasma shot. We successfully measured the time-dependent density and line-integrated density fluctuation radial profiles in a single plasma shot using the multichannel microwave interferometer. Thus, we have developed a useful tool for studying the improvement in plasma confinement by the formation of plasma confinement potential.