Gradient-echo EPI using a high-degree shim insert coil at 7 T: Implications for BOLD fMRI.

Gradient-echo EPI using a high-degree shim insert coil at 7 T: Implications for BOLD fMRI.
复制标题

DOI:
10.1002/mrm.26563
复制
发表时间:
2017-11
影响因子:
3.3
通讯作者:
Pan JW
Pan JW
中科院分区:
医学3区
文献类型:
--
作者:
Kim T;Lee Y;Zhao T;Hetherington HP;Pan JW

文献摘要

参考文献

被引文献

相似文献

To quantitatively assess the effects of high degree and order (1st–4th+) relative to 1st–2nd degree B 0 shimming at 7 Tesla (T) on gradient‐echo echo planar imaging (GE‐EPI) and blood‐oxygen‐level dependent (BOLD) activation. Simulations and GE‐EPI were performed at (2mm)3 and (3mm)3 resolution, evaluating the temporal signal‐to‐noise ratio (tSNR), transverse relaxivity ( ), BOLD % signal change and activated pixel counts in a breath‐hold task. Comparing the 1st–4th+ degree with 1st–2nd degree shimmed B 0 maps generated spatially varying regions of . As binned in 10‐Hz intervals, the two center Δ|B 0| (±10 Hz) bins maintained the B 0 offset of 48.6% of gray‐matter pixels. In the positive Δ|B 0| bins greater than 10 Hz, the 1st–4th+degree shimming improved the B 0 offset in 41.1%; in negative Δ|B 0| bins less than −10 Hz, the offset worsened in 10.2% of the pixels. In the positive Δ|B 0| bins, we found variable but significant increases in BOLD sensitivity; the negative Δ|B 0| bins showed significant decreases. In the breath‐hold studies, positive bins showed significantly increased activated pixel numbers (+5–29%), whereas negative bins showed −18 to 0% decline. 1st–4th+ degree shimming maintained B 0 homogeneity over central brain regions while improving most of the other regions, including the inferior frontal lobe. Magn Reson Med 78:1734–1745, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
DOI: 10.1016/j.neuroimage.2009.10.002
发表时间: 2010-01-15
期刊: NEUROIMAGE
影响因子: 5.7
作者:
Marques, Jose P.;Kober, Tobias;Gruetter, Rolf
通讯作者: Gruetter, Rolf
DOI: 10.1002/mrm.1910340111
发表时间: 1995-07-01
影响因子: 3.3
作者:
JEZZARD, P;BALABAN, RS
通讯作者: BALABAN, RS
DOI: 10.1002/mrm.1910380316
发表时间: 1997-09-01
影响因子: 3.3
作者:
Morrell, G;Spielman, D
通讯作者: Spielman, D
动态多型技术技术(炸药)在7特斯拉的人脑回声 - 平面成像。
DOI: 10.1016/j.neuroimage.2014.11.011
发表时间: 2015-01-15
期刊: NeuroImage
影响因子: 5.7
作者:
Juchem C;Umesh Rudrapatna S;Nixon TW;de Graaf RA
通讯作者: de Graaf RA
DOI: 10.1002/mrm.1910360125
发表时间: 1996-07-01
影响因子: 3.3
作者:
Blamire, AM;Rothman, DL;Nixon, T
通讯作者: Nixon, T