Infrared imaging video bolometer for the large helical device
Infrared imaging video bolometer for the large helical device
复制标题
大型螺旋装置红外成像视频测辐射热计
DOI:
10.1063/1.1319597
复制
发表时间:
2001
影响因子:
1.6
通讯作者:
N. Ashikawa
中科院分区:
文献类型:
--
作者:
B. Peterson;M. Osakabe;M. Shoji;N. Ashikawa
A new type of infrared imaging bolometer, known as the infrared imaging video bolometer (IRVB) has been under development at the National Institute of Fusion Science (NIFS) over the last year. A prototype of this diagnostic has been designed and constructed at NIFS and installed on the large helical device (LHD) and successfully operated. This diagnostic utilizes a 66×90×0.001 mm gold foil mounted in a frame to detect the radiation and neutrals from the plasma which are incident on the foil through a 1 cm diameter pinhole. The resulting temperature distribution on the foil is measured using an AGEMA THV 900 LW infrared camera having 136×272 pixels with a frame rate of 15 Hz and a nominal sensitivity of 80 mK. An image of the foil and surrounding frame consisting of 120×160 pixels is resampled down to 12×16 pixels using a linear interpolation scheme. Using a numerical technique the spatial and temporal derivatives of the temperature distribution on the foil are calculated and the incident power density on ...