Experimental Evaluation of Structural Performance of Foundation Beams under RC Shear Walls with Door openings
Experimental Evaluation of Structural Performance of Foundation Beams under RC Shear Walls with Door openings
复制标题
门洞钢筋混凝土剪力墙下基础梁结构性能试验评价
DOI:
10.1002/2475-8876.12191
复制
发表时间:
2021
影响因子:
0.9
通讯作者:
楠原文雄ほか
中科院分区:
文献类型:
--
作者:
鈴木卓;真田靖;市之瀬敏勝;楠原文雄ほか
An occurrence of brittle failure of a foundation beam under shear walls with door openings, similar to that in boundary beams between door openings on upper floors, is also a concern. Therefore, this study conducted static loading tests of foundation beam specimens under shear walls with door openings to investigate their structural performance. This paper reports the experimental results upon the restoring force characteristics and cracking pattern in the beam specimens and proposes an ultimate strength evaluation method for the foundation beams under shear walls with door openings.