A NEW METHOD FOR PREPARING FLAVIN-ADENINE DINUCLEOTIDE
A NEW METHOD FOR PREPARING FLAVIN-ADENINE DINUCLEOTIDE
复制标题
DOI:
10.1042/bj0540437
复制
发表时间:
1953-01-01
影响因子:
4.1
通讯作者:
WHITBY, LG
中科院分区:
文献类型:
--
作者:
WHITBY, LG
Chromatography on powdered cellulose was used to prepare flavinadenine dinucleotide (FAD) of 90% purity, free from contamination by other flavins and from contamination by compounds which absorb light between 240 and 510 m[mu]. The molecular extinction coefficients of FAD were reinvestigated. The possibility is discussed that the diminution in the absorption of FAD, at pH 7.0, relative to the combined absorption of its components (flavin mononucleotide and adenosine-5[image]-phosphate), is analogous to the quenching of fluorescence of FAD under similar conditions and is due to the formation of an internal complex.