The development and initial evaluation of a realistic simulated SPECT dataset with simultaneous respiratory and cardiac motion for gated myocardial perfusion SPECT.
The development and initial evaluation of a realistic simulated SPECT dataset with simultaneous respiratory and cardiac motion for gated myocardial perfusion SPECT.
复制标题
对封闭心肌灌注SPECT的同时呼吸和心脏运动的现实模拟SPECT数据集的开发和初步评估。
DOI:
10.1088/0031-9155/60/4/1399
复制
发表时间:
2015-02-21
影响因子:
3.5
通讯作者:
Tsui BM
中科院分区:
文献类型:
--
作者:
Lee TS;Tsui BM
We developed a realistic simulation dataset for simultaneous respiratory and cardiac (R&C) gated SPECT/CT using the 4D NURBS-based Cardiac-Torso (NCAT) Phantom and Monte Carlo simulation methods, and evaluated it for a sample application study. The 4D NCAT phantom included realistic respiratory motion and beating heart motion based on respiratory gated CT and cardiac tagged MRI data of normal human subjects. To model the respiratory motion, a set of 24 separate 3D NCAT phantoms excluding the heart was generated over a respiratory cycle. The beating heart motion was modelled separately with 48 frames per cardiac cycle for each of the 24 respiratory phases. The resultant set of 24×48 3D NCAT phantoms provides a realistic model of a normal human subject at different phases of combined R&C motions. An almost noise-free SPECT projection dataset for each of the 1,152 3D NCAT phantoms was generated using Monte Carlo simulation techniques and the radioactivity uptake distribution of 99mTc sestamibi in different organs. By grouping and summing the separate projection datasets, separate or simultaneous R&C gated acquired data with different gating schemes could be simulated. In the initial evaluation, we combined the projection datasets into no gating, 6 respiratory-gates only, 8 cardiac-gates only, and combined 6 respiratory-gates & 8 cardiac-gates projection datasets. Each dataset was reconstructed using 3D OS-EM without and with attenuation correction using the averaged and respiratory-gated attenuation maps, and the resulting reconstructed images were compared. These results were used to demonstrate the effects of R&C motions and the reduction of image artifact due to R&C motions by gating and attenuation corrections. We concluded that the realistic 4D NCAT phantom and Monte Carlo simulated SPECT projection datasets with R&C motions are powerful tools in the study of the effects of R&C motions, as well as in the development of R&C gating schemes and motion correction methods for improved SPECT/CT imaging.
登录
查看更多内容
影响因子:
3.8
作者:
Dawood, Mohammad;Buether, Florian;Schaefers, Klaus P.
通讯作者:
Schaefers, Klaus P.
影响因子:
3.5
作者:
He, B;Du, Y;Frey, EC
通讯作者:
Frey, EC
影响因子:
2.4
作者:
Cho, K;Kumiata, S;Kumazaki, T
通讯作者:
Kumazaki, T
影响因子:
1.8
作者:
Klein, GJ;Reutter, BW;Huesman, RH
通讯作者:
Huesman, RH
影响因子:
3.5
作者:
Lamare, F.;Carbayo, M. J. Ledesma;Visvikis, D.
通讯作者:
Visvikis, D.