Dielectric characterization of biocompatible hydrogels for application to Epidermal RFID devices
Dielectric characterization of biocompatible hydrogels for application to Epidermal RFID devices
复制标题
用于表皮 RFID 设备的生物相容性水凝胶的介电特性
DOI:
--
复制
发表时间:
2015
期刊:
影响因子:
--
通讯作者:
G. Marrocco
中科院分区:
文献类型:
--
作者:
S. Amendola;C. Occhiuzzi;A. Ajovalasit;M. Sabatino;C. Dispenza;G. Marrocco
Functionalized skin-like membranes are currently under investigation for the design of a new class of Epidermal Electronics devices for sensing and healing applications. The dynamic response of epidermal antennas in presence of absorption and release of fluids is a key-point to design RFID radio-sensors and actuators. This paper addresses the characterization of the dielectric property of PVA-based biocompatible hydrogel membranes in the UHF RFID band by means of a modified ring resonator. Samples having different compositions are measured in the dry state as well as when exposed to a progressive release of body fluids emulating perspirations or wound exudates. It was found that the permittivity increases up to 10 times demonstrating that such membranes may be also used as sensors.