Mass Spectrometric Detection of Gaseous Hydrogen Peroxide in Ambient Air Using Dielectric Barrier Discharge as an Excitation Source
Mass Spectrometric Detection of Gaseous Hydrogen Peroxide in Ambient Air Using Dielectric Barrier Discharge as an Excitation Source
复制标题
DOI:
10.1246/cl.2009.520
复制
发表时间:
2009-06-05
影响因子:
1.6
通讯作者:
Hiraoka, Kenzo
中科院分区:
文献类型:
--
作者:
Chen, Lee Chuin;Suzuki, Hiroaki;Hiraoka, Kenzo
Real-time detection of gaseous hydrogen peroxide (H2O2) in ambient air is an important subject for public safety and security. We have developed a mass spectrometric detection system for gaseous H2O2 using dielectric barrier discharge as the excitation source for metastable rare gas atoms. The O-2(-) ion produced by Penning ionization of ambient air forms a stable cluster ion [H2O2 + O-2](-) which is detected by an orthogonal time-of-flight mass spectrometer. No interference by the moisture in the air was observed.