M. Halbwachs;J. Grangeon;J. Sabroux;A. Villevielle
A gas-lift experiment was tested on the deep waters of Lake Monoun, Cameroon, in March-April 1992. Two polyethylene pipes were used: a 53 mm inner-diameter (length 90 m), and a 141 mm inner-diameter (length 65 m). After the gas-lift was primed and a steady flow of diphasic fluid was established at the pipe outled, the observed flow-rates of carbon dioxide were 15 and 151 l (STP) per second, respectively. Complete degassing of Lake Monoun would take less than one year with three 141 mm diameter pipes