Influence of intraocular pressure and trabeculotomy on aqueous outflow in enucleated monkey eyes.
Influence of intraocular pressure and trabeculotomy on aqueous outflow in enucleated monkey eyes.
复制标题
眼压和小梁切开术对摘除猴眼房水流出的影响。
DOI:
--
复制
发表时间:
1971
期刊:
影响因子:
--
通讯作者:
W. M. Grant
中科院分区:
文献类型:
--
作者:
Ellingsen Ba;W. M. Grant
Quantitative aqueous perfusion was performed at a series of pressures from 5 to 50 mm. Hg in enucleated monkey eyes on which an iridotomy had been performed to minimize artificial changes in depth of the anterior chamber. Total facility of outflow became less when the pressure was increased, similar to what was observed in separately reported experiments on enucleated human eyes. When the pressure was next reduced, total facility tended to increase in monkey eyes, though not in human eyes. Trabeculotomy of one quadrant from within the anterior chamber in monkey eyes made the total facility of outflow several times greater than normal and was calculated to eliminate 83 to 97 per cent of the resistance to outflow in the traheculotomized quadrant.