PULSE-BY-PULSE PHOTON BEAM POSITION MEASUREMENTS AT THE SPring-8 UNDULATOR BEAMLINE*
PULSE-BY-PULSE PHOTON BEAM POSITION MEASUREMENTS AT THE SPring-8 UNDULATOR BEAMLINE*
复制标题
Spring-8 波荡器光束线上的逐脉冲光子束位置测量*
DOI:
--
复制
发表时间:
--
期刊:
影响因子:
--
通讯作者:
S. Takahashi
中科院分区:
文献类型:
--
作者:
H. Aoyagi;H. Osawa;K. Kobayashi;T. Fujita;S. Takahashi
A pulse-mode X-ray beam position monitor that enables pulse-by-pulse position measurement in the synchrotron radiation beamline of the synchrotron radiation facility was improved, and evaluation tests were performed. The monitor was equipped with blade-shaped detection elements utilizing diamond heatsinks to reduce stray capacitance, and a microstrip transmission line to improve high-frequency characteristics. The detection elements operate as photocathodes and generate single unipolar pulses with a full width at a half-maximum of less than 1 ns. This operation allows pulse-by-pulse measurement of the synchrotron radiation beam. To ensure operations at the undulator beamline in SPring-8, where the synchrotron radiation power is very intense, further improvements were introduced to the detecting elements to enhance heat resistance. The evaluation results of sensitivity and resolution in the pulse-by-pulse photon measurement and observation of beam oscillation during beam injection are discussed herein.