AC Losses in HTS Coils Wound with Bi-2223 Tapes

AC Losses in HTS Coils Wound with Bi-2223 Tapes
复制标题

使用 Bi-2223 胶带缠绕的 HTS 线圈的交流损耗

DOI:
10.1007/978-4-431-66877-0_225
复制
发表时间:
2000
期刊:
影响因子:
--
通讯作者:
H. Hayashi
H. Hayashi
中科院分区:
--
文献类型:
--
作者:
Kenzo Fukushige;M. Nakagami;K. Watabe;F. Sumiyoshi;H. Hayashi

文献摘要

被引文献

相似文献

在液氮中用电测量了Bi-2223多芯带材双饼形线圈的交流损耗。所观察到的交流损耗具有很强的频率依赖性,这表明磁滞损耗不是主要的损耗分量。线圈中的损耗,这是运输电流的依赖,是从两个到十倍以上的预期从短样品测试。
AC loss measurement for Bi-2223 multifilamentary tapes wound into double pancake coils was carried out electrically in liquid nitrogen. The observed ac losses have strong frequency dependence, which indicates that hysteresis losses are not the main loss component. The loss in coils, which is transport current dependant, is from two to more than ten times larger than that expected from the short sample test.