An SPM8-based approach for attenuation correction combining segmentation and nonrigid template formation: application to simultaneous PET/MR brain imaging.

An SPM8-based approach for attenuation correction combining segmentation and nonrigid template formation: application to simultaneous PET/MR brain imaging.
复制标题

DOI:
10.2967/jnumed.113.136341
复制
发表时间:
2014-11
期刊:
Journal of nuclear medicine : official publication, Society of Nuclear Medicine
影响因子:
--
通讯作者:
Catana C
Catana C
中科院分区:
其他
文献类型:
--
作者:
Izquierdo-Garcia D;Hansen AE;Förster S;Benoit D;Schachoff S;Fürst S;Chen KT;Chonde DB;Catana C

文献摘要

参考文献

被引文献

相似文献

We present an approach for head MR-based attenuation correction (MR-AC) based on the Statistical Parametric Mapping (SPM8) software that combines segmentation- and atlas-based features to provide a robust technique to generate attenuation maps (µ-maps) from MR data in integrated PET/MR scanners. Coregistered anatomical MR and CT images acquired in 15 glioblastoma subjects were used to generate the templates. The MR images from these subjects were first segmented into 6 tissue classes (gray and white matter, cerebro-spinal fluid, bone and soft tissue, and air), which were then non-rigidly coregistered using a diffeomorphic approach. A similar procedure was used to coregister the anatomical MR data for a new subject to the template. Finally, the CT-like images obtained by applying the inverse transformations were converted to linear attenuation coefficients (LACs) to be used for AC of PET data. The method was validated on sixteen new subjects with brain tumors (N=12) or mild cognitive impairment (N=4) who underwent CT and PET/MR scans. The µ-maps and corresponding reconstructed PET images were compared to those obtained using the gold standard CT-based approach and the Dixon-based method available on the Siemens Biograph mMR scanner. Relative change (RC) images were generated in each case and voxel- and region of interest (ROI)-based analyses were performed. The leave-one-out cross-validation analysis of the data from the 15 atlas-generation subjects showed small errors in brain LACs (RC=1.38%±4.52%) compared to the gold standard. Similar results (RC=1.86±4.06%) were obtained from the analysis of the atlas-validation datasets. The voxel- and ROI-based analysis of the corresponding reconstructed PET images revealed quantification errors of 3.87±5.0% and 2.74±2.28%, respectively. The Dixon-based method performed substantially worse (the mean RC values were 13.0±10.25% and 9.38±4.97%, respectively). Areas closer to skull showed the largest improvement. We have presented an SPM8-based approach for deriving the head µ-map from MR data to be used for PET AC in integrated PET/MR scanners. Its implementation is straightforward and only requires the morphological data acquired with a single MR sequence. The method is very accurate and robust, combining the strengths of both segmentation- and atlas-based approaches while minimizing their drawbacks.
DOI: 10.1007/s00259-012-2113-0
发表时间: 2012-07-01
影响因子: 9.1
作者:
Samarin, Andrei;Burger, Cyrill;Kuhn, Felix P.
通讯作者: Kuhn, Felix P.
DOI: 10.2967/jnumed.107.049353
发表时间: 2008-11-01
影响因子: 9.3
作者:
Hofmann, Matthias;Steinke, Florian;Pichler, Bernd J.
通讯作者: Pichler, Bernd J.
DOI: 10.2967/jnumed.108.054726
发表时间: 2009-04-01
影响因子: 9.3
作者:
Martinez-Moeller, Axel;Souvatzoglou, Michael;Nekolla, Stephan G.
通讯作者: Nekolla, Stephan G.
DOI: 10.1148/radiol.2262012141
发表时间: 2003-02-01
期刊: RADIOLOGY
影响因子: 19.7
作者:
Goerres, GW;Ziegler, SI;Buck, A
通讯作者: Buck, A
DOI: 10.1007/s00259-002-0796-3
发表时间: 2002-07-01
影响因子: 9.1
作者:
Burger, C;Goerres, G;von Schulthess, GK
通讯作者: von Schulthess, GK