Gel-exclusion chromatography on S1000 Sephacryl: application to phospholipid vesicles.
Gel-exclusion chromatography on S1000 Sephacryl: application to phospholipid vesicles.
复制标题
S1000 Sephacryl 上的凝胶排阻色谱:应用于磷脂囊泡。
DOI:
10.1016/0003-2697(83)90618-8
复制
发表时间:
1983
影响因子:
2.9
通讯作者:
Tanford,C
中科院分区:
文献类型:
--
作者:
Reynolds,JA;Nozaki,Y;Tanford,C
Sephacryl S1000 has an exclusion diameter of approximately 3000 Å and is thus an appropriate gel exclusion medium for size analysis and fractionation of phospholipid vesicles. Calibration is conveniently carried out using polystyrene beads of known diameter eluted with a detergent-containing buffer. Recovery of phospholipid vesicles of different sizes from S1000 presaturated with lipid is greater than 95%, and diameters obtained from a calibration curve using the polystyrene beads are in good agreement with those obtained by negative contrast electron microscopy.