Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts -: Time window and threshold in microbubble numbers
Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts -: Time window and threshold in microbubble numbers
复制标题
DOI:
10.1161/01.str.31.7.1640
复制
发表时间:
2000-07-01
期刊:
影响因子:
8.3
通讯作者:
Ringelstein, EB
中科院分区:
文献类型:
--
作者:
Droste, DW;Silling, K;Ringelstein, EB
Background and Purpose-Cardiac right-to-left shunts can be identified by transesophageal. echocardiography (TEE) and by transcranial Doppler ultrasound (TCD) with the use of contrast agents and a Varsalva maneuver (VM) as provocation procedure. Currently, data on the appropriate timing of the VM, the use of a diagnostic time window, and a threshold in contrast agent microbubbles detected are insufficient.Methods-Fifty-eight patients were investigated by both TEE and bilateral TCD of the middle cerebral artery. The following protocol with injections of 10 mt of the commercial galactose-based contrast agent Echovist was applied in a randomized way: (1) no VM, (2) VM for 5 seconds starting 2 seconds after the beginning of contrast injection, (3) VM for 5 seconds starting 5 seconds after the beginning of contrast injection, (4) VM for 5 seconds starting 8 seconds after the beginning of contrast injection, and (5) repetitive short VMs in between 2 and 13 seconds after the beginning of contrast injection. In addition to the single tests, we also tested the sensitivity and specificity of combined results of the tests with VM.Results-In 21 patients, a right-to-left shunt was demonstrated by TEE and contrast TCD (shunt positive). Twenty-one patients were negative in both investigations, no patient was positive on TEE and negative on TCD, and 16 patients were only positive on at least I TCD investigation but negative during TEE. Test 3 was the most appropriate test when combined with the results of 1 of the other tests with VM. The highest sensitivities were achieved with a diagnostic time window of 40 seconds and when the presence of a single microbubble was sufficient for the diagnosis of a shunt.Conclusions-TCD performed twice with 2 provocation maneuvers with Echovist is a sensitive method to identify TEE-proven cardiac right-to-left shunts. The VM should be performed for 5 seconds starting at 5 seconds after the beginning of contrast injection.