Simulation and analysis of the electromyographic interference pattern in normal muscle. Part I: Turns and amplitude measurements
Simulation and analysis of the electromyographic interference pattern in normal muscle. Part I: Turns and amplitude measurements
复制标题
正常肌肉肌电干扰图的模拟与分析。
DOI:
10.1002/mus.880090507
复制
发表时间:
1986
期刊:
影响因子:
3.4
通讯作者:
E. Stålberg
中科院分区:
文献类型:
--
作者:
S. Nandedkar;D. Sanders;E. Stålberg
The electromyographic (EMG) interference pattern (IP) was simulated by adding together motor unit action potentials (MUAPs) of different sizes that had been recorded by a concentric needle EMG electrode. The number of turns (NT) of the simulated IP increased with the number of MUAP discharges. The mean amplitude (MA) difference between successive turns in the IP increased when large amplitude MUAPs were added. Our analysis demonstrates that the MA of the IP is determined mainly by the amplitude of large MUAPs in the signal and that large amplitude spikes are more likely to be generated by single large amplitude MUAPs than by summation of several small amplitude MUAPs.