Plasma‐modified Nylon 4 membrane for dialysis
Plasma‐modified Nylon 4 membrane for dialysis
复制标题
用于透析的等离子体改性尼龙 4 膜
DOI:
10.1002/app.1989.070370603
复制
发表时间:
1989
影响因子:
3
通讯作者:
C. Chou
中科院分区:
文献类型:
--
作者:
J. Lai;C. Chou
The effects of plasma treatment conditions, such as supply power, treatment time, gases used in reactor, surface energy, water content, dialysis permeability, partition coefficient, diffusion coefficient, and free volume of Nylon 4 membranes, were studied. The solutes considered for dialysis system were NaCl, urea, and MgCl2. The permeabilities of NaCl and urea of membranes with plasma treated in argon at 80 W for 20 min are 5.57 × 10−5 and 5.89 × 10−5 cm2/min, respectively. Much higher permeabilities of NaCl and urea obtained by oxygen plasma-treated membranes under 20 W and for 20 min are 30.74 × 10−5 and 17.66 10−5 cm2/min, respectively, compared to that of untreated Nylon 4 membranes.